Omron G6A-434P General purpose 4 pole change over contact relay. Coil voltage 4.5 - 7.5V Nominal 6V.
Omron G6A-434P General purpose 4 pole change over contact relay. Coil voltage 6V.
MPN: G6A-434P-ST-US
Basic Parameters:
Features:
Download the datasheet here: Omron_G6A.pdf
The full item Part number being sold is G6A-434P-ST-US
Characteristics:
Contact resistance: 50 mW max.
Operate (set) time Single-side stable types: 4PDT :7 ms max. (mean value: approx. 3.8 ms)
Release (reset) time: 4PDT: 5 ms max. (mean value: approx. 1.3 ms)
Bounce time Operate: mean value: approx. 0.5 ms
Release: mean value: approx. 0.5 ms
Min. set/reset signal width : 15 ms min.
Max. operating frequency Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MW min. (at 500 VDC); except for set-reset
Dielectric strengtn 1,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
250 VAC, 50/60 Hz for 1 min between set and reset coils
Impulse withstand voltage 1,500 V 10 x 160 ms (conforms to FCC Part 68)
Vibration resistance Destruction: 10 to 55 Hz, 5-mm double amplitude
Malfunction: 10 to 55 Hz, 3.3-mm double amplitude
Shock resistance Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: DPDT: 500 m/s2 (approx. 50G)
4PDT, Latching type: 300 m/s2 (approx. 30G)
Life expectancy Mechanical: 100,000,000 operations min. (at 36,000 operations/hr)
Electrical: 500,000 operations min. (at 1,800 operations/hr)
Ambient temperature Operating: –40°C to 70°C (with no icing)
Storage: –40°C to 70°C (with no icing)
Ambient humidity Operating: 45% to 85%
Weight: Approx. 6 g